SR036DB1
Inductorless Switching Power Supply
Introduction
The Supertex SR036 is an inductorless, dual output off-line
regulator intended for 120/240VAC line operation. The
operating principle is to activate a pass element between
line and load only when the input voltage is lower than a
certain value. Thus conduction only occurs with a low
voltage drop across the pass element, resulting in more
efficient operation compared to a standard linear regulator.
The SR036DB1 demo board contains all the circuitry
needed to supply a low-current (<40mA) load. Included are
input protection circuitry, a full wave bridge rectifier, a pass
element, and output capacitors.
Specifications
AC Input
24VAC to 264VAC
40Hz to 100Hz
Output Voltages
V
UNREG
V
REG
18V±20%
3.3V ±10%
Output Current
I
UNREG
+ I
REG
40mA @ 120VAC
30mA @ 240VAC
Efficiency
AC
IN
=120VAC 60Hz, I
U
=40mA, I
R
=0mA
40% typ
Board Layout and Connections





D










Z
1
F
1
1
IC
1
C
1
C
2
Q
1
V
REG
V
UNREG
GND
WARNING!!!
Do not connect to scope ground or to the ground of other
earth-grounded instruments. Doing so will short the AC line,
resulting in damage to the circuit and/or instrument. Either
use an isolation transformer on the AC line, use a differential
probe, or use a floating, battery-powered instrument to make
measurements.
WARNING!!!
No galvanic isolation. Dangerous voltages are
present when connected to the AC mains.
AC
IN
AC
IN
Connect to the AC line. Neutral to top, hot to bottom.
GND
Circuit common.
Note that since galvanic isolation is not provided, connecting
this point to an earth-grounded instrument (such as an
oscilloscope) will short the AC line, resulting in circuit and/or
instrument damage.
Also note that GND may be at a higher potential with respect
to earth ground, even if the AC is switched off. Use caution!
Do not connect to earth-ground.
V
UNREG
The unregulated output. Nominal output voltage is 18 volts.
This output will have a certain amount of 120Hz ripple,
depending on load.
Do not connect to earth-grounded loads.
V
REG
The regulated output. 5V nominal output voltage.
Do not connect to earth-grounded loads.
Fuse
The AC input is fused to protect against overloads. It should
be replaced with a 125mA, 250V standard 3AG fuse.
16APR02
1
SR036DB1
Inductorless Switching Power Supply
SR036 Circuit
SR036
Q
1
VN2460N8
C
1
220µF
C
2
1µF
V
UNREG
V
REG
AC
IN
F
1
125mA
Z
1
P6KE400CA
IC
1
D
1
Parts List
Desig Description
Part
Number
F
1
Fuse, 3AG, 125mA, 250V
Z
1
Transient voltage suppressor, 400V
P6KE400CA
D
1
Diode bridge, 1A, 600V
IC
1
HV Supply Controller
Supertex SR036SG
Q
1
MOSFET, 600V N-channel
Supertex VN2460N8
C
1
Capacitor, alum, 220µF, 35V
C
2
Capacitor, cer, 1µF, 16V
Modifications
The SR036DB1 may be modified to provide higher output current. Remove Q1 and replace with a D-Pak N-channel MOSFET with
a voltage rating appropriate for the input voltage. The on resistance of the replacement FET is not as important as the gate
threshold voltage ­ the lower the threshold voltage, the more efficient the converter.

To reduce ripple at the higher output current, C1 may be replaced with a higher value capacitor.
16APR02
2