ChipFind - Datasheet

Part Number MBR10xx

Download:  PDF   ZIP
MBR1020
THRU
MBR10100
10 Amp
Schottky Barrier
Rectifier
Features
Maximum Ratings
·
Operating Temperature: -55
°
C to +150
°
C
·
Storage Temperature: -55
°
C to +175
°
C
Microsemi
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MBR1020
MBR1020 20V 14V 20V
MBR1030 MBR1030

30V 21V 30V
MBR 1035 MBR1035
35V 24.5V 35V
MBR1040
MBR1040
40V 28V 40V
MBR1045
MBR1045
45V 31.5V 45V
MBR1060
MBR1060
60V 42V 60V
MBR10100
MBR10100
100V 70V 100V
Electrical Characteristics @ 25
°
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
10A T
C
= 125
°
C
Peak Forward Surge
Current
I
FSM
150A 8.3ms, half sine
*Pulse test: Pulse width 300
µ
sec, Duty cycle 1%
www.
mccsemi
.com
Maximum Forward
Voltage Drop Per
Element
A
B
C
K
J
I
G
F
E
D
N
M
L
H
PIN 1
PIN 2
CASE
PIN
1
2
INCHES MM
A .560 .625 14.22 15.88
B .380 .420 9.65 10.67
C .100 .135 2.54 3.43
D .230 .270 5.84 6.86
E .380 .420 9.65 10.67
F ------ .250 ------ 6.35
G .500 .580 12.70 14.73
H .190 .210 4.83 5.33
I .020 .045 0.51 1.14
J .012 .025 0.30 0.64
K .139 .161 3.53 4.09
L .140 .190 3.56 4.83
M .045 .055 1.14 1.40
N .080 .115 2.03 2.92

C
J


400pF


Measured at
1.0MHz, V
R
=4.0V









·
Metal of siliconrectifier, majonty carrier conducton
·
Guard ring for transient protection
·
Low power loss high efficiency
·
High surge capacity, High current capability
TO-220AC
20 to 100 Volts
MBR1080 MBR1080 80V 56V 80V





www.
mccsemi
.com
Typical Junction
Capacitance


MBR1020-1045
MBR1045-1060
MBR1080-10100
V
F
.84V I
FM
= 20 A mper
T
A
=
I = 10 A mper
FM
.84V
.95V

25
°
C


IR
0.15mA
0.1mA T
J
= 25
°
C

MBR1020-1045
MBR1060-10100

Maximum DC
Reverse Current At
Rated DC Blocking
Voltage

omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
MBR1020 thru MBR10100
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°
C
Figure 3
Forward Derating Curve
25 50 100 125 150
0
0
5
6
7
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°
C
75
8
9
10
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.
2 .7
.3 .4 .5 .6
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
°
C
40
60
100
.8
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20 150
50 75 100 125
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
175
T
J
=25
°
C
www.
mccsemi
.com
M C C
1 100
4
0
25
50
75
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20
60 80
40
100
125
150
MBR1080-10100
MBR1020-1045
MBR1060