ChipFind - Datasheet

Part Number MB50xW

Download:  PDF   ZIP
MB5005W
THRU
MB5010W
50 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
MB-50W
Features
·
Mounting Hole For #8 Screw
·
Plastic Case With Metal Bottom
·
Any Mounting Position
·
Surge Rating Of 400 Amps
DIMENSIONS
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A
---
1.140
---
29.00
B
---
.452
---
11.50
C
---
.750
---
19.10
D
.692
.732
17.6
18.6
E
.040
---
1.00
---
4PL/TYP
G
.188
---
4.77
---
H
.429
.468
10.9
11.9
Maximum Ratings
·
Operating Temperature: -50
°
C to +150
°
C
·
Storage Temperature: -50
°
C to +150
°
C
MCC
Catalog
Number
Device
Marking
Maximum
Reccurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MB5005W MB5005W 50V 35V 50V
MB501W MB501W 100V 70V 100V
MB502W MB502W 200V 140V 200V
MB504W MB504W 400V 280V 400V
MB506W MB506W 600V 420V 600V
MB508W MB508W 800V 560V 800V
MB5010W MB5010W 1000v 700V 1000v
Electrical Characteristics @ 25
°
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
50.0A
T
J
= 55
°
C
Peak Forward Surge
Current
I
FSM
400A
8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
V
F
1.2V I
FM
= 25A per
element;
T
J
= 25
°
C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
10
µ
A
0.5mA
T
J
= 25
°
C
T
J
= 100
°
C
*Pulse test: Pulse width 300
µ
sec, Duty cycle 1%
B
C
E
D
AC
+
-
A
AC
G
A
H
D
www.
mccsemi
.com
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
MB5005W thru MB5010W
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
°
C
Figure 3
Forward Derating Curve
25
50
100
150
175
0
0
10
20
30
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°
C
75
40
50
60
1
100
4
0
100
200
300
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60 80
40
00
400
500
600
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20
120
40
60
80
100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
T
J
=25
°
C
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2
1.2
.4
.6
.8
1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
°
C
40
60
100
1.4
www.
mccsemi
.com
M C C