ChipFind - Datasheet

Part Number BAW56

Download:  PDF   ZIP
Jun-03-2003
1
BAW56...
Silicon Switching Diode
·
For high-speed switching applications
·
Common anode configuration
BAW56S
BAW56U
BAW56
BAW56T
BAW56W
!
,
,
,
!
"
#
$
,
, !
, "
Type
Package
Configuration
Marking
BAW56
BAW56S
BAW56T
BAW56U
BAW56W
SOT23
SOT363
SC75
SC74
SOT323
common anode
double common anode
common anode
double common anode
common anode
A1s
A1s
A1s
A1s
A1s
Jun-03-2003
2
BAW56...
Maximum Ratings at T
A
= 25°C, unless otherwise specified
Parameter
Symbol
Value
Unit
Diode reverse voltage
V
R
80
V
Peak reverse voltage
V
RM
85
Forward current
I
F
200
mA
Surge forward current, t = 1 µs
I
FS
4.5
A
Total power dissipation
BAW56, T
S
31°C
BAW56S, T
S
85°C
BAW56T, T
S
104°C
BAW56U, T
S
90°C
BAW56W, T
S
103°C
P
tot
330
250
250
250
250
mW
Junction temperature
T
j
150
°C
Storage temperature
T
stg
-65 ... 150
Thermal Resistance
Parameter
Symbol
Value
Unit
Junction - soldering point
1)
BAW56
BAW56S
BAW56T
BAW56U
BAW56W
R
thJS
360
260
185
240
190
K/W
1
For calculation of R
thJA
please refer to Application Note Thermal Resistance
Jun-03-2003
3
BAW56...
Electrical Characteristics at T
A
= 25°C, unless otherwise specified
Parameter
Symbol
Values
Unit
min.
typ.
max.
DC Characteristics
Breakdown voltage
I
(BR)
= 100 µA
V
(BR)
85
-
-
V
Reverse current
V
R
= 70 V
V
R
= 25 V, T
A
= 150 °C
V
R
= 70 V, T
A
= 150 °C
I
R
-
-
-
-
-
-
0.15
30
50
µA
Forward voltage
I
F
= 1 mA
I
F
= 10 mA
I
F
= 50 mA
I
F
= 100 mA
I
F
= 150 mA
V
F
-
-
-
-
-
-
-
-
-
-
715
855
1000
1200
1250
mV
AC Characteristics
Diode capacitance
V
R
= 0 V, f = 1 MHz
C
T
-
-
2
pF
Reverse recovery time
I
F
= 10 mA, I
R
= 10 mA, measured at I
R
= 1mA,
R
L
= 100
t
rr
-
-
4
ns
Test circuit for reverse recovery time
EHN00019
F
D.U.T.
Oscillograph
Pulse generator: t
p
= 100ns, D = 0.05, t
r
= 0.6ns,
R
i
= 50
Oscillograph: R = 50
, t
r
= 0.35ns, C
1pF
Jun-03-2003
4
BAW56...
Reverse current I
R
=
(T
A
)
V
R
= Parameter
0
25
50
75
100
°C
150
T
A
1
10
2
10
3
10
4
10
5
10
nA
I
R
70 V
25 V
Forward Voltage V
F
=
(T
A
)
I
F
= Parameter
-40
-20
0
20
40
60
80
100
140
T
A
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.2
V
F
IF = 150mA
IF = 100mA
IF = 50mA
IF = 10mA
IF = 1mA
IF = 0,1mA
Forward current I
F
=
(V
F
)
T
A
= 25°C
EHB00091
BAW 56
F
150
mA
100
50
0
V
F
1.5
V
1.0
0.5
0
typ
max
Peak forward current I
FM
=
(t
p
)
T
A
= 25°C
BAW56
EHB00092
BAW 56
s
0
10
-1
10
-2
10
-3
10
-4
10
-5
10
10
-6
p
t
p
t
T
=
D
T
0.2
0.1
0.05
0.02
0.01
= 0.005
D
10
-2
10
-1
A
10
0
10
1
10
FM
2
t
Jun-03-2003
5
BAW56...
Forward current I
F
=
(T
S
)
BAW56
0
15
30
45
60
75
90 105 120 °C
150
T
S
0
25
50
75
100
125
150
175
200
mA
250
I
F
Forward current I
F
=
(T
S
)
BAW56S
0
15
30
45
60
75
90 105 120 °C
150
T
S
0
25
50
75
100
125
150
175
200
mA
250
I
F
Kei
Forward current I
F
=
(T
S
)
BAW56U
0
15
30
45
60
75
90 105 120 °C
150
T
S
0
25
50
75
100
125
150
175
200
mA
250
I
F
Forward current I
F
=
(T
S
)
BAW56W
0
15
30
45
60
75
90 105 120 °C
150
T
S
0
25
50
75
100
125
150
175
200
mA
250

I
F