ChipFind - Datasheet

Part Number 2RI100G

Download:  PDF   ZIP
2RI100G
(2x100A)
POWER DIODE MODULE
1200V,1600V / 100A
2 in one-package
Features
· Glass Passivation Chip
· Easy Connection
· Insulated Type
Applications
· Inverters
· Battery Chargers
· DC Motors
· General Purpose DC Power Supplies
Maximum ratings and characteristics
Absolute maximum ratings
Outline Drawings, mm
Item
Repetitive peak reverse voltage
Non-repetitive peak reverse voltage
Average output current
Surge current
I
2
t
Operating junction temperature
Storage temperature
Isolation voltage
Screw torque
Symbol
V
RRM
V
RSM
I
O
I
FSM
I
2
t
T
j
T
stg
V
is
Conditions
From rated load, Sine wave 10ms
From rated load
2 x 100
2000
16000
-40 to +150
-40 to +125
AC2500(1min.)
3.5 *1
Unit
V
V
A
A
A
2
s
°C
°C
V
N·m
50/60Hz Sine wave, Tc=98°C
Rating
-120 -160
1200 1600
1320 1760
*1: Recommendable value : 2.5 to 3.0 N·m(M5)
~ + -
1
2
3
Electrical characteristics (Ta=25°C Unless otherwise specified )
Item
Forward voltage drop
Reverse current
Symbol
V
FM
I
RRM
Conditions
Tj=25°C, I
FM
=320A
Tj=150°C, V
R
=V
RRM
Unit
V
mA
Min. Typ. Max.
1.40
30
*
: With Thermal Compound
Thermal Characteristics
Min. Typ. Max.
Symbol
R
th(j-c)
R
th(c-f)
Conditions
Junction to case
the base to cooling fin *
0.20
0.10
Unit
°C/W
°C/W
Item
Thermal resistance
Inner Curcuit Schematic
Characteristics
Forward Characteristics
Forward voltage : V
F
[V]
Forward Average Current : I
F
[V]
Forward current : I
F
[A]
Power Loss : Po [W]
320
280
240
200
160
120
80
40
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
0 20 40 60 80 100 120
Case T
emperature : T
C
C]
Surge Current : I
FSM
[A]
0.03 0.05 0.1 0.3 0.5 1
2000
1600
1200
800
400
0
time : t [sec.]
Thermal resistance : Zth(j-c) [
°
C
/
W
]
0.20
130
120
110
100
90
80
70
120
100
80
60
40
20
0
2RI100G(2x100A)
POWER DIODE MODULE
Forward Average Current vs. Power Loss
Forward Average Current vs. Case Temperature
Surge Current
Transient Thermal Impedance
Forward Average Current : I
F
[V]
time : t [sec.]
0.10
0
10
-3
10
-2
10
-1
10
0
10
1
0 20 40 60 80 100 120
Type.
Max.
Half sine wave
Half sine wave
Square wave
Conduction angle
=120
°
Square wave
Conduction angle
=120
°
Surge current